Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.unach.edu.ec/handle/51000/13046| Título : | Efectos del tiempo de polimerización de la resina nano híbrida Bio Crown impresa en 3D. |
| Autor : | Carrillo Vaca, David Gerardo Carballo Aguilar, Angie Giovanna Coyago Cholango, Jefferson Omar |
| Palabras clave : | Resistencia compresiva Rugosidad Prizma bio Crown Shore Cavidad Oral Estética Dureza Fotopolimerización |
| Fecha de publicación : | 27-may-2024 |
| Editorial : | Riobamba: Universidad Nacional de Chimborazo |
| Citación : | Carballo Aguilar, A. - Coyago Cholango, J. (2024) Efectos del tiempo de polimerización de la resina nano híbrida Bio Crown impresa en 3D. (Tesis de Grado) Universidad Nacional de Chimborazo. Riobamba, Ecuador. |
| Resumen : | La presente investigación tuvo como objetivo evaluar rugosidad y dureza de la resina Prizma Bio Crown impresa en 3D con diferentes tiempos de polimerización, mediante un estudio In-vitro de tipo experimental, observacional, con enfoque cuantitativo. Se realizaron 100 muestras con dimensiones de 12 mm de alto por 6 mm de ancho, divididos en 5 grupos de polimerización: grupo A- 0 minutos, grupo B- 5 minutos, grupo C- 10 minutos, grupo D-15 minutos, grupo E- 20 minutos. Las muestras fueron sometidas a ensayos de rugosidad en la máquina Surfest SJ-210 del laboratorio de investigación, desarrollo en nuevas tecnologías de diseño de la EPN. La media de rugosidad del grupo A fue de 2.97925 µm, grupo B de 2.3455 µm, C 1.18825 µm, grupo D 0.898 µm, grupo E 0.8005 µm. evidenciando que existe una diferencia significativa en relación con el tiempo de post-curado, donde se mostró que el grupo E es el que mejor superficie lisa presento. A su vez los ensayos realizados en el centro de transparencia y tecnología de la UTA indican una variación en la dureza short D-ISO 868 concordante con el tiempo de polimerización obtenido en la rugosidad con valores de grupo A de 92,88, en el grupo B con 89,6, en el grupo C con 92,22, en el grupo D con 92,6 y en el grupo E con 93,9, comprobando que el grupo E tuvo resultados favorables y demostrando que la relación del pulido y el tiempo de fotopolimerización si influye de manera muy significativa a pesar de que no hubo diferencias de valores notables.Concluyendo, que un correcto protocolo de pulido y un post-procesado (polimerización) de las resinas 3D, pueden brindar un impacto significativo en las propiedades físicas del material, asegurando una correcta estética, funcionalidad y durabilidad de las restauraciones en la cavidad oral. |
| Descripción : | The objective of this research was to evaluate the roughness and hardness of the 3D printed Prizma Bio Crown resin with different polymerization times, through an experimental, observational, in-vitro study with a quantitative approach. 100 samples were made with dimensions of 12 mm high by 6 mm wide, divided into 5 polymerization groups: group A- 0 minutes, group B- 5 minutes, group C- 10 minutes, group D-15 minutes, group E - 20 minutes. The samples were subjected to roughness tests on the Surfest SJ-210 machine from the EPN's research and development laboratory in new design technologies. The average roughness of group A was 2.97925 µm, group B 2.3455 µm, C 1.18825 µm, group D 0.898 µm, group E 0.8005 µm. evidencing that there is a significant difference in relation to the post-curing time, where it was shown that group E is the one with the best smooth surface. At the same time, the tests carried out at the UTA transparency and technology center indicate a variation in the short D-ISO 868 hardness consistent with the polymerization time obtained in the roughness with group A values of 92.88, in the group B with 89.6, in group C with 92.22, in group D with 92.6 and in group E with 93.9, proving that group E had favorable results and demonstrating that the relationship between polishing and photopolymerization time does have a very significant influence although there were no notable differences in values. Concluding, that a correct polishing protocol and post-processing (polymerization) of the 3D resins can provide a significant impact on the physical properties of the material, ensuring correct aesthetics, functionality, and durability of the restorations in the oral cavity. |
| URI : | http://dspace.unach.edu.ec/handle/51000/13046 |
| ISSN : | UNACH-FCS-ODON |
| Aparece en las colecciones: | Tesis Odontología Tesis Odontología |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| Carballo Aguilar, A. - Coyago Cholango, J. (2024) Efectos del tiempo de polimerización de la resina nano hibrida Bio Crown con impesión 3D..pdf | 2,46 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.
