<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>DSpace Community:</title>
    <link>http://dspace.unach.edu.ec/handle/51000/350</link>
    <description />
    <pubDate>Tue, 18 Aug 2026 09:01:11 GMT</pubDate>
    <dc:date>2026-08-18T09:01:11Z</dc:date>
    <image>
      <title>DSpace Community:</title>
      <url>http://localhost:80/jspui/retrieve/24810/Civil.png</url>
      <link>http://dspace.unach.edu.ec/handle/51000/350</link>
    </image>
    <item>
      <title>Estudio comparativo de sistemas de muros de acero vs arriostramientos concéntricos en edificios de mediana altura de acero en Riobamba.</title>
      <link>http://dspace.unach.edu.ec/handle/51000/17323</link>
      <description>Title: Estudio comparativo de sistemas de muros de acero vs arriostramientos concéntricos en edificios de mediana altura de acero en Riobamba.
Authors: Maji Paguay, Antony Alexis
Abstract: Resumen: Embargo
Description: Abstract: Embargo</description>
      <pubDate>Wed, 05 Aug 2026 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://dspace.unach.edu.ec/handle/51000/17323</guid>
      <dc:date>2026-08-05T00:00:00Z</dc:date>
    </item>
    <item>
      <title>Modelación hidráulica con escenarios de cambio climático en la quebrada Las Abras, cantón Riobamba, provincia de Chimborazo</title>
      <link>http://dspace.unach.edu.ec/handle/51000/17315</link>
      <description>Title: Modelación hidráulica con escenarios de cambio climático en la quebrada Las Abras, cantón Riobamba, provincia de Chimborazo
Authors: Clavijo Quintero, Cristhian Adrian
Abstract: Resumen: Embargo
Description: Abstract: Embargo</description>
      <pubDate>Mon, 03 Aug 2026 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://dspace.unach.edu.ec/handle/51000/17315</guid>
      <dc:date>2026-08-03T00:00:00Z</dc:date>
    </item>
    <item>
      <title>Evaluación de resistencia y densidad del hormigón con sustitución parcial de cemento por flujos piroclásticos del volcán Tungurahua y Sangay.</title>
      <link>http://dspace.unach.edu.ec/handle/51000/17296</link>
      <description>Title: Evaluación de resistencia y densidad del hormigón con sustitución parcial de cemento por flujos piroclásticos del volcán Tungurahua y Sangay.
Authors: Maiza Yanchaguano, Darwin Lizandro
Abstract: Esta investigación evaluó la sustitución parcial de cemento HE Chimborazo por piroclasto triturado de los volcanes Tungurahua y Sangay. Inicialmente, los materiales fueron caracterizados mediante ensayos físicos y químicos, y se elaboraron mezclas con sustituciones del 3 %, 4 % y 5 % para determinar el porcentaje óptimo de reemplazo. Los resultados permitieron seleccionar el 4 %, debido a mayor resistencia a la compresión y un comportamiento uniforme. Posteriormente, se desarrolló la fase experimental definitiva con dosificación de 1:1.53:1.65:0.52 y se evaluaron propiedades del hormigón en estado fresco y endurecido a los 7, 14, 21 y 28 días. &#xD;
El hormigón con piroclasto del volcán Tungurahua alcanzó una resistencia a la compresión de 37.65 MPa a los 28 días, superando en 4.27 % al hormigón convencional, mientras que el del Sangay un incremento de 1.16 %. Este comportamiento se asoció al contenido de SiO₂ y al efecto filler. Además, las mezclas con piroclasto presentaron ligeras reducciones de densidad y aumentos de permeabilidad, manteniendo valores de 10⁻⁵ cm/s, característicos de hormigones convencionales. Se concluyó que la sustitución parcial del 4 % de cemento por piroclasto triturado del volcán Tungurahua es técnicamente viable para su aplicación en hormigón estructural.
Description: This study evaluated the partial replacement of HE Chimborazo cement with crushed pyroclastic material from the Tungurahua and Sangay volcanoes. Initially, the materials were characterized through physical and chemical tests, and concrete mixtures with 3%, 4%, and 5% cement replacement were prepared to determine the optimal substitution percentage. The results identified 4% as the optimal replacement level due to its higher compressive strength and more uniform performance. Subsequently, the definitive experimental phase was carried out using a mix proportion of 1:1.53:1.65:0.52, and fresh and hardened concrete properties were evaluated at 7, 14, 21, and 28 days of curing.&#xD;
Concrete incorporating Tungurahua pyroclastic material achieved a compressive strength of 37.65 MPa at 28 days, exceeding conventional concrete by 4.27%, while the Sangay material showed an increase of 1.16%. This behavior was associated with the SiO₂ content and the filler effect. In addition, the mixtures containing pyroclastic material exhibited slight reductions in density and increases in permeability, while maintaining values on the order of 10⁻⁵ cm/s, characteristic of conventional concrete. It was concluded that the partial replacement of 4% of cement with crushed pyroclastic material from the Tungurahua volcano is technically feasible for structural concrete applications.</description>
      <pubDate>Tue, 28 Jul 2026 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://dspace.unach.edu.ec/handle/51000/17296</guid>
      <dc:date>2026-07-28T00:00:00Z</dc:date>
    </item>
    <item>
      <title>Estudio del coeficiente de consumo horario residencial de agua potable en la ciudad de Patate</title>
      <link>http://dspace.unach.edu.ec/handle/51000/17265</link>
      <description>Title: Estudio del coeficiente de consumo horario residencial de agua potable en la ciudad de Patate
Authors: Veloz Mena, Daniel Sebastián
Abstract: Hoy en día el manejo y gestión del agua potable en el país se ha mantenido con pocos y ligeros cambios con respecto a anteriores años, en ocasiones, dejando de lado revisiones y actualizaciones de información necesarias para efectuar: acciones, diseños y decisiones con respecto al recurso hídrico o factores poblacionales que puedan estar afectando al mismo. Manteniendo planes de diseño antiguos, los cuales, están dados en base a rangos obsoletos presentados por la normativa impuesta años atrás, dejando de lado la importancia que pueden tener ciertos factores con respecto al consumo hídrico. La presente investigación tiene como finalidad la obtención de curvas de consumo horario residencial en el cantón Patate, al igual que identificar y relacionar diversos factores urbanísticos, socioeconómicos e hidráulicos que puedan influir el consumo horario residencial. La investigación se realizó mediante la ayuda de encuestas elaboradas a diversas familias residentes del lugar, obtención y procesamiento de datos de consumo por medio de medidores de agua en un rango de 24 horas por 7 días. Con la curva de consumo horario se evidenció un rango de consumo elevado de 13h00 a 14h00 en los estratos A, B, C y D, con un pico máximo de 120.09 l/h, también se presentó un coeficiente de consumo horario máximo calculado con un valor de 2.92, el cual podría ser apropiado para futuros diseños en la parroquia de Patate. Todos los resultados presentados en este trabajo de investigación se han presentado de manera gráfica y detallada con el fin de ayudar a las entidades competentes en búsqueda de una mejora en la gestión y manejo del recurso hídrico en Patate.
Description: Today, the management of drinking water in the country has remained largely unchanged from previous years, with only minor adjustments; at times, this has led to a neglect of the reviews and updates of information necessary to carry out actions, designs, and decisions regarding water resources or population factors that may be affecting them. By maintaining outdated design plans; which are based on obsolete ranges established by regulations-imposed years ago, the importance of certain factors related to water consumption is overlooked. The purpose of this study is to obtain hourly residential consumption curves in the Patate canton and to identify and correlate urban planning, socioeconomic, and hydraulic factors that may influence them. The research was conducted through surveys administered to various local households, as well as by collecting and processing 24-hour consumption data from water meters over 7 days. The hourly consumption curve showed a high consumption range from 1:00 p.m. to 2:00 p.m. across socioeconomic strata A, B, C, and D, with a peak of 120.09 l/h. A maximum hourly consumption coefficient of 2.92 was also calculated, which may be appropriate for future designs in the parish of Patate. All results from this study are presented graphically and in detail to assist the relevant authorities in their efforts to improve water resource management in Patate.</description>
      <pubDate>Wed, 22 Jul 2026 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://dspace.unach.edu.ec/handle/51000/17265</guid>
      <dc:date>2026-07-22T00:00:00Z</dc:date>
    </item>
  </channel>
</rss>

